Knowledge

How to Measure The Accuracy of Single Axis Guide Arm?

How to measure the accuracy of linear module, Single Axis Guide Arm?



Single Axis Guide Arm or linear module is a mechanical part of linear transmission. It has wide application fields, easy installation and high precision. However, linear module is only an instrument, and the oscillation produced by long-term work will also change its accuracy. Therefore, it is necessary to pay attention from time to time to see whether its accuracy is still at the local level originally set. So, how to measure the accuracy of linear module?


Method 1: when measuring the accuracy of the positioning accuracy Single Axis Guide Arm, take its maximum stroke as the reference length, and then mark it with the absolute value of the maximum error between the distance from the reference orientation to practice and the command value.


Method 2: repeated positioning accuracy: repeatedly locate any point on Single Axis Guide Arm in the same direction, and then measure the dead center direction. After servo electric cylinder, calculate one-half of the maximum difference of meter reading as the inspection criterion. Then, detect the azimuth separation at the center and roughly both ends of the moving distance, take the maximum value in the inspection value as the measured value, and mark it with half of the maximum difference with positive and negative.


Method 3: for working parallelism, place a standard ruler on the platform of high-quality and durableSingle Axis Guide Arm, and measure and check the scale limit that the experimental indicator can move with the inner slider. The maximum difference of readings within the moving scale limit of linear motor is the measured value.


Method 4: to measure the accuracy of the clearance Single Axis Guide Arm, first feed the inner slider, and take the reading of the experimental indicator when the slider just moves as the benchmark. Take this as the preliminary. Without relying on the feeding equipment, the micro electric steel applies the load in the same direction as the moving direction of the inner slider, and then take the difference between the reference value at the preliminary inspection and the azimuth at the return as the measured value. The accuracy check of linear module is carried out in the direction of the center and roughly both ends of the moving part, and the maximum value of the obtained value is taken as the measured value.


Linear module is an automatic mechanical instrument, which is not as flexible as manual machinery. Therefore, in practical work, it is necessary to master the change of its accuracy, so it is necessary to use the above methods to measure linear module. Together, the orthogonal manipulator must select Single Axis Guide Arm with guaranteed quality in order to maximize the basic accuracy of the linear module.

You are welcome to visit video centre of Tallman Robotics Limited to watch more projects and appliations.

Prev:

Next:

Leave a message