Engineered organism motion with tailored solution creates mechanical intelligence to redefine possibility frontier!

IndustriesSemiconductor & Electronics

How Is a Linear Module Used in an IC Tray Loading Machine?

This article will discuss linear module for IC tray loading, a key process in the electronics and semiconductor industry.

Author: ShanGong, Director of Engineering Department | Published: 22 October 2026 | Category: Semiconductor & Electronics

TMS62 ball screw linear module standing vertical as a tray elevator, lifting a stack of JEDEC trays for IC tray loading.

Every IC tray loading machine is built from linear axes, and choosing the right linear module for each axis starts with the tray. The machine lifts a stack, separates the top tray and carries it to a pick station. There it clamps the tray, and once the devices are out, it restacks it.

In the loaders reviewed for this guide, ball screw modules lift the stacks, while screw or belt modules carry the trays. The pick head is a separate decision, driven by how fast it must work.

This guide sizes each linear module for IC tray loading from one object, the 322.6 × 135.9 mm JEDEC tray. It finishes with a TMS62 configuration and a checklist you can send to our engineers.

Follow the Tray: Five Linear Module Moves in IC Tray Loading

What linear module is used in an IC tray loader? That depends on where the axis sits in the tray’s journey. A typical loader moves each tray through five steps:

  1. Lift: an elevator raises the input stack so the top tray reaches the transfer level.
  2. Separate: a singulator lifts or slides the top tray clear of the one below.
  3. Transfer: a shuttle carries the tray to the pick station.
  4. Register: a clamp pushes the tray against its datum edges, and the pick head works through the pockets.
  5. Restack: the processed tray moves on, and an output elevator stacks it.

In IC tray loading, these moves call for two kinds of linear module. Lift and restack are vertical axes that carry the whole stack, so thrust and a brake come first. Transfer and register, by contrast, are short horizontal moves where the repeat stop matters most. Meanwhile, the pick head follows its own rules, because its drive depends on the throughput it must reach.

Machines come in two main architectures. A top-of-stack feeder works down a single stack; for example, the JEDEC tray stack feeder from TrayFeeders holds 30 thin or 20 thick trays this way. A random-access magazine instead addresses trays by slot, which suits sorting and mixed-part jobs.

Five-step IC tray loader path from input stack to output stack, with the linear module drive for each axis.High-throughput handlers keep the same split. Yokogawa’s 2001 technical report on its HS2000 IC handler treats the tray elevator and stacker as subsystems in their own right, separate from the pick axes. For a wider view of motion in back-end tools, see our guide to linear actuators in semiconductor equipment.

The JEDEC Tray Sets the Numbers

Every JEDEC matrix tray shares one outline, 322.6 × 135.9 mm (12.7 × 5.35 in), according to WikiChip’s JEDEC tray entry. Thickness comes in two common profiles: about 6.35 mm for low-profile trays and about 10.16 mm for high-profile trays, as TopLine’s guide to JEDEC tray thickness and bake ratings explains.

JEDEC registers the individual families as outlines, for example CO-028 (thick matrix tray for BGA) and CO-029 (thin matrix tray for BGA). The full list is in the JEDEC matrix tray outlines index.

Tray profileOutlineThicknessStack capacity in a published feeder
Low profile (thin)322.6 × 135.9 mm≈ 6.35 mm30 trays (TrayFeeders JTF2)
High profile (thick)322.6 × 135.9 mm≈ 10.16 mm20 trays (TrayFeeders JTF2)

JEDEC matrix tray drawing showing the 322.6 × 135.9 mm outline, datum edges and thin versus thick tray profiles.

Because the outline is fixed, each linear module in an IC tray loading machine can be sized once for every JEDEC family. Only the thickness and the pocket layout change between products, and the loader controller holds both as recipe values.

Two tray features drive the mechanics. The pocket matrix fixes where devices sit, while the datum edges and the chamfered pin-1 corner let a clamp register the tray. Keep each stack to one tray design, too, because nesting features differ between families.

Heat history matters as well. TopLine rates bakeable trays at 140–180 °C, with a typical bake at 125 °C. Repeated bake cycles can leave a tray slightly warped, and any warp shows up later at the clamp.

IC Tray Loading Linear Module Map: Which Module Fits Each Axis

Start with the third column of the table below. Whatever limits precision on an axis also points to its drive.

SubsystemMotionWhat limits precisionTypical driveTallMan module family
Stack elevatorVertical, one tray per stepTray thickness, top-of-stack sensingBall screw module with brakeScrew-driven modules
SingulatorShort lift or slideTray-to-tray separationPneumatic or short screw axisShort-stroke screw modules
Tray shuttleHorizontal transferRepeat stop at the clampBall screw or belt moduleScrew- or belt-driven modules
Clamp and positionerShort push to datumTray datum and warpShort screw axis or pneumaticShort-stroke screw modules
Pick X / YMoves over the pocket matrixVision window, throughputScrew or belt (benchtop); linear motor (high UPH)Screw / belt modules; linear motors
Pick ZShort vertical strokePocket depth, contact forceScrew axis, or voice coilCompact screw modules
Output restackVertical stackingTray thicknessBall screw module with brakeScrew-driven modules

Off-the-shelf linear modules are a normal choice for IC tray loading axes. mk Group, for instance, describes a tray handling system built on a three-axis gantry of timing-belt linear modules. Our screw-driven linear modules and belt-driven linear modules cover the families in the last column.

Looking for IC tray loading automation solutions? Send us your tray layout, and our engineers will propose a module for each axis.

Sizing the Tray Elevator

How does a JEDEC tray stacker elevator work? It raises the stack one tray thickness at a time, so the top tray always arrives at the same transfer level. Once the stack is empty, the carriage returns to the bottom for reloading.

For that duty in IC tray loading, the best linear module for a JEDEC tray elevator is usually a ball screw module with a brake motor. A screw holds a vertical load in place and repeats each step closely. It also delivers high thrust at a 5 mm or 10 mm lead.

Elevator Stroke From Stack Height

Stack height is the tray count multiplied by the tray thickness. The elevator stroke then adds a margin for lift-off and separation:

stroke = (trays × tray thickness) + separation margin

where The separation margin comes from the singulator design; 60 mm is used below as an example input

StackTray thicknessStack heightStroke with 60 mm margin
30 thin trays6.35 mm190.5 mm250.5 mm
20 thick trays10.16 mm203.2 mm263.2 mm

 

Both stacks fit inside a 300 mm stroke, so a 300 mm module is a sensible first choice for a 20–30 tray elevator. Even so, size the margin from your own singulator rather than from this example.

The singulator decides that margin. One common design slides retractable fingers under the rim of the second tray, so the elevator can lower the stack away from the top tray. Another lifts the top tray clear with a short vertical axis. In both cases, the elevator needs enough travel for the mechanism to work above a full stack.

Tray elevator side view showing a 30-tray stack, 60 mm separation margin and 250.5 mm stroke within 300 mm.Step From Tray Thickness

With a 10 mm lead, one motor turn moves the carriage 10 mm. A 6.35 mm thin-tray step is therefore 0.635 of a motor turn, and a 10.16 mm thick-tray step is 1.016 turns. Thin and thick trays share the same mechanics; only the recipe changes.

Speed is seldom the bottleneck on this axis. At 500 mm/s, a full 300 mm return takes 0.6 s plus acceleration, and a one-tray step takes far less. By that arithmetic, singulation and settling are likely to take longer than the elevator move itself.

In practice, the elevator should stop on the tray rather than on a count. A top-of-stack sensor closes the loop, because trays vary slightly in thickness and baked trays can warp.

Common mistake: Indexing the elevator by motor count alone. Small differences in tray thickness and warp add up over a 30-tray stack, so the top tray drifts away from the transfer level.

Brake Motor and Stack Load

In IC tray loading, a full stack must stay put when power drops, so every vertical linear module we supply is specified with a brake motor. With a client-supplied motor (code CU), the client provides the brake version, usually a Delta or local-brand servo, and the B in the model code records it. The brake adds about 30 mm to the module’s overall length.

Loaded tray mass varies with tray material, pocket count and device type, so it has to be measured rather than assumed. Weigh one loaded tray, multiply by the tray count and add the carriage plate. The total must stay within the module’s vertical rating:

maximum trays = (vertical rating − carriage plate mass) ÷ loaded tray mass

where Use the vertical rating for the lead you choose; on the TMS62 it is 12 kg at lead 5 or lead 10

If the stack is too heavy, a finer lead will not help, because lead 5 and lead 10 share the same 12 kg vertical rating on the TMS62. Instead, shorten the stack or move to a larger frame.

Random-Access Magazines

In a random-access magazine, the elevator must reach any slot on demand, not just the next one. Slot pitch and repeat position therefore matter more than a top sensor. TrayFeeders’ random-access JEDEC tray handler, for example, holds up to 18 thin trays per magazine with a 5–10 s exchange. For random-access IC tray loading, a ball screw linear module that repeats to ±0.01 mm suits this kind of addressing.

Sizing the Shuttle Linear Module for IC Tray Loading

In IC tray loading, the shuttle linear module carries each tray from the stack to the pick station, where a clamp registers it. Afterwards, the processed tray either returns along the same path or moves on to an output stack, depending on the layout.

Shuttle Stroke From Tray Length

The shuttle must carry the full 322.6 mm tray length clear of the stack, plus some clear-out. With an assumed 40 mm clear-out, for example, the travel is 322.6 + 40 = 362.6 mm. The next standard stroke in 50 mm steps is therefore 400 mm.

Each extra tray position at the pick station adds another tray pitch. Lines that also run non-JEDEC matrix trays may need a larger envelope; Europlacer’s tray loader, for instance, accepts trays up to 340 × 190 × 13 mm.

Tray shuttle plan view with a 400 mm stroke, plus a ball screw versus belt linear module comparison table.

Ball Screw vs Belt Linear Module for Tray Handling

When comparing a ball screw vs belt linear module for tray handling, look first at how the shuttle stops. TallMan’s confirmed repeatability is ±0.01 mm for screw modules and ±0.03 mm for belt modules.

PropertyBall screw moduleBelt module
Repeatability (TallMan)±0.01 mm±0.03 mm
Best shuttle useShort, repeatable stops at a clampLong transfers between stations
Vertical useYes, with brake motorYes, with brake motor

In a single-station loader, the shuttle stops at the same clamp position every cycle, so a screw module is the natural choice. A belt module earns its place when one long axis carries trays between the input stack, the pick station and the output stack. On that kind of axis the travel is long and the stops are few, while the clamp still fixes the final position.

TechMan’s guides cover screw linear module selection and belt linear module accuracy in more depth.

Clamp, Datum and Tray Warp

The clamp, not the shuttle, decides where the pockets end up. It pushes the tray against its datum edges, so the tray’s own tolerance and any warp fix the final pocket position. Vision at the pick head then corrects what remains.

Common mistake: Specifying a tighter shuttle to cure mispicks. If the tray is warped or the clamp misses the datum, a more precise axis changes nothing; fix the clamp or add vision.

The Pick Gantry Over the Pocket Matrix

The pick-and-place gantry works over the clamped tray. Its X travel must cover the 322.6 mm tray length and its Y travel the 135.9 mm width for each tray position. The outline gives a conservative limit, because pocket centres sit inside the tray edge. On top of that, add the nozzle offset and the move to the place position, such as a socket or a carrier tape.

Pick gantry plan view over two JEDEC tray positions, showing travel limits and drive choices by throughput class.

The Z axis needs only enough stroke to reach the pocket floor and clear the tray wall, so a compact screw axis usually covers it. Contact force on the device is then managed by nozzle compliance or by the servo drive.

For the pick head, throughput decides which linear module an IC tray loading gantry needs. Benchtop and programming loaders, such as Exatron’s tabletop test IC handler with two JEDEC tray positions, work at a pace that screw or belt gantries can match. Our 3 axis Cartesian robots fit that class.

High-throughput test handlers are different. Yokogawa’s HS2000 loader runs on linear motors, and ETEL describes direct-drive handler axes across turret handlers. For that class of IC tray handling, see our article on linear motors for IC test handlers.

Worked Example: TMS62 Linear Module for a Benchtop IC Tray Loading Elevator

As a compact linear module for benchtop IC tray loaders, the TMS62 suits the elevator sized above. The configuration below, TMS62-L10S300, uses our 62 mm-wide semi-closed body. It is the base configuration; for IC tray loading, the elevator version of this linear module adds a brake motor.

ItemTMS62-L10S300What it means for a tray elevator
Body62 mm wide, semi-closed (CM), direct motor mounting (N)Compact enough for benchtop loaders
DriveØ16 ball screw, 10 mm lead, C70.635 motor turn per thin-tray step
Stroke300 mm (standard range 50–1,050 mm in 50 mm steps)Covers a 30-thin or 20-thick stack with a 60 mm margin
Speed500 mm/s at 3,000 rpm0.6 s for a full 300 mm return, plus acceleration
Payload (lead 10)20 kg horizontal, 12 kg verticalCheck 12 kg against your weighed full stack
Rated thrust (lead 10)720 N 
Repeatability±0.01 mm (P7); ±0.005 mm (P5)P5 available for tighter registration
Guide and sensorsOne 15 × 12.5 rail; SK-SX672 origin sensor, or SL-W1R5MC1 inside the bodyInside sensor keeps wiring off the tray area
Motor400 W, client-supplied (base model shown with a Delta servo)Brake version required for an elevator

Lead Choice and Model Code

On the TMS62, lead 5 nearly doubles the rated thrust to 1,364 N at half the speed, and the vertical rating stays at 12 kg. Lead 20, however, drops the vertical rating to 4 kg, and lead 32 has no vertical rating listed. Elevators therefore stay on lead 5 or lead 10.

The full model code reads TMS62-L10S300-CU400-C2U-NCM-P7, and each block maps to one choice:

  1. TMS62: TallMan screw module, 62 mm frame.
  2. L10S300: 10 mm lead and 300 mm stroke.
  3. CU400: client-supplied 400 W motor. For an elevator, order CU400B, the brake version.
  4. C2U: sensor position, quantity and mounting.
  5. NCM: direct motor mounting (N) on a semi-closed body (CM).
  6. P7: ±0.01 mm repeatability grade; P5 gives ±0.005 mm.

TMS62 linear module base configuration with 300 mm stroke and 400 W servo, used to size an IC tray loading elevator.

Have a tray elevator or shuttle to size? Tell us the tray type, stack count and target exchange time, and you will receive 3D and 2D PDF drawings to confirm. Every TMS frame, lead and stroke is listed in our linear module e-catalogue. Request drawings

ESD and Cleanroom Fit for an IC Tray Loading Linear Module

An ESD-safe linear module for IC tray handling starts with grounding, not with the module alone. The cell should run under an ESD control programme such as ANSI/ESD S20.20, with every module body on a defined earth path. Trays help as well: TopLine notes that carbon-loaded JEDEC trays are conductive or dissipative.

Particles are the second concern, because the trays are open while devices are picked. The TMS62-CM is a semi-closed linear module, which suits many benchtop IC tray loading and test-floor cells. Where a module runs directly above open trays in a tighter cleanroom, however, a fully closed module is the safer choice. The cell owner sets the target class under ISO 14644-1 cleanroom classes.

Our article on closed and open linear modules compares the two structures, and our fully closed linear modules page lists the range.

Layout matters as much as the module. Where possible, mount the elevators and the shuttle below or beside the tray plane, so moving parts do not pass over open pockets. In addition, route drag chains and sensor cables away from the tray area, or choose the inside-sensor option.

Preferred and avoided linear module layouts in an IC tray loader cell, showing earth bonding and cable routing.

Linear Module Checklist for IC Tray Loading

Use this linear module selection guide for semiconductor tray handling when briefing our engineers:

  1. Trays: JEDEC thin, thick or custom, and the tray family.
  2. Stacks: trays per stack, input and output.
  3. Stack mass: weight of one loaded tray.
  4. Exchange time: seconds per tray change.
  5. Architecture: top-of-stack or random-access magazine.
  6. Tray positions: how many trays sit at the pick station.
  7. Pick rate: units per hour and nozzle count.
  8. Environment: ESD programme and cleanroom class.
  9. Interfaces: handshake I/O, SMEMA or SECS/GEM, and your controller.
  10. Motors: your preferred brand with brake versions for vertical axes, or motors you will supply.

Our engineers reply with 3D and 2D PDF drawings for your approval.

Ten-item specification checklist for choosing a linear module for IC tray loading, from tray type to motors. 

IC Tray Loading Linear Module FAQ

What linear module is used in an IC tray loader?

Ball screw modules with brake motors usually lift the stacks, and screw or belt modules move trays to the pick station. Pick gantries vary with throughput: benchtop loaders suit screw or belt axes, whereas high-UPH test handlers move to linear motors.

How does a JEDEC tray stacker elevator work?

It raises the stack in steps of one tray thickness, stopping on a top-of-stack sensor. In a random-access magazine, by contrast, the elevator moves to any numbered slot, so slot pitch replaces the top sensor.

How much stroke does a tray elevator need for 30 trays?

For 30 low-profile trays, the stack is 190.5 mm, so a 300 mm stroke covers it with a 60 mm margin. Thirty high-profile trays make a 304.8 mm stack, however, which calls for a 400 mm stroke once the margin is added.

Can one linear module handle thin and thick trays in IC tray loading?

Usually, yes: the same linear module serves both profiles in IC tray loading. The outline does not change, so the module needs only a different step (6.35 or 10.16 mm) and stack count, both set in the recipe. Before running both, check that the singulator fingers and clamp height suit each profile.

Does a tray elevator need a brake motor?

Yes. Without one, a full stack would drop when power is cut. With a client-supplied motor, order the brake version (CU400B on a TMS62) and allow about 30 mm of extra module length.

Which ball screw lead suits a tray elevator?

On the TMS62, lead 10 gives 500 mm/s and 720 N, while lead 5 gives 250 mm/s and 1,364 N. Both carry 12 kg vertically, so choose lead 5 when thrust or finer resolution matters more than return speed.

Are semi-closed linear modules suitable for ESD-sensitive IC tray loading?

Yes, provided the module body is bonded to the cell’s earth path and the cell runs an ESD programme such as ANSI/ESD S20.20. The module’s openness matters more for particles than for static; for that, see our fully closed linear modules.

Can TallMan supply linear module drawings for IC tray loading machines?

Yes. Our engineers prepare 3D models and 2D PDF drawings for every linear module in your IC tray loading layout. The linear module e-catalogue lists every TMS frame, lead and stroke.

Conclusion

Sizing each linear module for IC tray loading means following the tray through the machine. Stack height and the singulator margin give the elevator stroke, while tray length gives the shuttle stroke. The pick gantry then takes its travel from the tray positions and its drive from the throughput.

Before choosing a standard module, run two checks: weigh the full stack against the vertical rating, and specify a brake on every vertical axis. Then send us the checklist, and our engineers will turn it into drawings. More examples are on our semiconductor and electronics applications page.

Send your tray layout for axis drawings →

About the author

ShanGong is Director of the Engineering Department at TallMan Robotics, with 10 years of experience in the linear motion industry. TallMan linear modules hold CE verification of compliance under the Low Voltage (LVD) and EMC directives. Watch our modules in production on YouTube, or follow us on LinkedIn.

References

  1. WikiChip, “JEDEC tray.” https://en.wikichip.org/wiki/jedec_tray
  2. TopLine, “JEDEC Trays.” https://topline.tv/JEDEC_Tray.html
  3. JEDEC, CO registration index. https://www.xyz.jedec.org/sites/default/files/COINDEX_0.pdf
  4. TrayFeeders, “JTF2 JEDEC Tray Stack Feeder.” https://www.trayfeeders.com/jedec-tray-stack-feeder
  5. TrayFeeders, “JTF3 Random Access JEDEC Tray Handler.” https://www.trayfeeders.com/random-access-jedec-tray-feeder
  6. Yokogawa Technical Report No. 32, “HS2000 and LT9730 Series of IC Handlers” (2001). https://web-material3.yokogawa.com/1/11336/tabs/rd-tr-r00032-003.pdf
  7. ETEL, “ETEL solution for IC turret handler” (2019). https://www.etel.ch/wp-content/uploads/2024/05/etel-solution-for-ic-turret-handler.pdf
  8. mk Group, “Tray Transfer and Handling System for IKLTs.” https://www.mk-group.com/en/references/reference/news/tray-transfer-and-handling-system-for-iklts.html
  9. Europlacer, “Tray Loader.” https://europlacer.com/product-tray-loader/
  10. Exatron, “Model 802 Tabletop Test IC Handler.” https://www.exatron.com/model-802-tabletop-test-ic-handler/
  11. ESD Association, ANSI/ESD S20.20-2021. https://www.esda.org/store/standards/product/314/ansiesd-s20-20-2021
  12. ISO 14644-1:2015, Cleanrooms and associated controlled environments. https://www.iso.org/standard/53394.html

Prev: